Modules EAS

picture

Central unit EOS/EAS 4.000

Main contol unit for dibalog systems;
TCP/IP, embedded file-based database (Nadcap) conform, Linux operating system;
Applicable in combination with dibalog modules and visualization software;

PM-Modul

- Power Measurement Module: Calculate your cost of electrical energy per load!
- Power measurement: 24/7 storage of consumption in kWh+preventive maintenance by heating monitoring: get an immediate alarm if your  electrical heating is broken or beginning to break.

IML10-module series 1 (10 inputs)

Measuring of currentsdirect transformer connection 1A secondary;
Applicable in combination with EOS central unit and EOS visualisation softwarere;

Counter module ZML series II

Recording of pulse signals and / or malfunction messages;
Inputs free definable via software;
Applicable in combination with EOS central unit and EOS visualisation software;

Current/voltage module UIML series I

For measuring of up to 4 voltages or currents within the specified range;
Inputs configurable per software;
Applicable in combination with EOS central unit and EOS visualisation software;

Temperature measuring module TML series II

For temperature measuring in combination with digital temperature sensors type TSL;
Applicable in combination with EOS central unit and EOS visualisation software;

TAML module series I

Display of temperature of one TSL measuring point;
Only in combination with TML (temperature;
Measuring module) and TSL (temperature sensor;

TSL3-sensor (temperature)

Digital temperature sensor applicable as room sensor;
Applicable in combination with TML (temperature measuring module);

TSL3A-sensor (temperature)

Digital temperature sensor for flat surfaces;
Applicable in combination with TML (temperature measuring module);

TSL3R-sensor (temperature)

Digital temperature sensor for pipes;
Applicable in combination with TML (temperature measuring module);

TSL3M-sensor (temperature)

Digital temperature sensor for fluids;
Applicable in combination with TML (temperature measuring module);

Multi-transducer-module MUM small series I (2 inputs)

Measuring of signals of e.g. thermocouples, current, voltage;
In combination with voltage-current-module type UIML;

Multi-transducer-module MUM Big series I (4 inputs)

Measuring of signals of e.g. thermocouples, current, voltage;
In combination with voltage-current-module type UIML;

picture

Worldwide leader for energie optimization systems - SAVING YOUR MONEY

Contact

dibalog USA Inc.
222 LaDean Ct. Suite A
Simpsonville, SC 29680
USA

Phone: +1 (888) 8699204
Email: info@dibalog.com